.. ############################################################################ .. manual/packages/vertex-cfd/nonlinear_solve_printing.rst .. ############################################################################ .. _sec_nonlinear_solve_printing: ******************** NOX Printing ******************** The ``Printing`` sublist controls the precision, processor, and diagnostic categories used by NOX output. .. dropdown:: :icon: multi-select :color: primary :animate: fade-in-slide-down .. py:data:: Output Precision :type: integer :value: Integer :usage: Optional :default: ``3`` :description: Sets the number of digits used by NOX diagnostic output. .. py:data:: Output Processor :type: integer :value: MPI rank :usage: Optional :default: ``0`` :description: Selects the MPI rank that writes NOX diagnostic output. .. dropdown:: Output Information :icon: bookmark :color: light :animate: fade-in-slide-down Each entry is an optional boolean that enables the matching NOX output category. Tempus enables ``Error``, ``Warning``, ``Linear Solver Details``, ``Stepper Iteration``, ``Stepper Details``, and ``Stepper Parameters`` by default; it disables ``Outer Iteration``, ``Parameters``, and ``Details``. The searched Vertex-CFD inputs override these settings to enable only ``Error`` and ``Warning``. Example ------- .. literalinclude:: ../../../../examples/inputs/simple_box_2d.xml :language: xml :linenos: :start-at: :end-at: :emphasize-lines: 2-14 :caption: NOX output configured to print only errors and warnings.